Profile: Infrastructure : Product Specifications Infrastructure product is sold in 3 ways: • Footprint : Floorspace provided on a per rack basis, each Footprint has power also provided on a per rack basis • Cabinet : A cabinet provisioned on a Footprint having an amount of power pre-provided • Floorspace: raw technical floorspace sold on a per m2 basis with power options bundled as packages and invoiced separately. All floorspace requests will however require a CDD.
Rack Space specifications Footprint is Floorspace provided on a per rack basis, each Footprint has power also provided on a per rack basis
ILA’s Only 600mm X 600mm Footprints are available within ILA’s. Footprints in ILA’s have front access only. 10A DC as standard
Regens and PoPs The Standard Footprint size capable of holding either a Footprint or a cabinet in PoPs and Regens is 600mm x 600mm or 600mm x 800mm. Footprints in Regens and PoPs are arranged in suite lines allowing Access to the front and rear of the Customer Equipment.
Standard Specification Total internal height 47U Front and back 19” Vertical mounting Key lockable front door DC LV breaker Panel (as required) Pre Cut Floor tile Cabinet provided in a shared area
Optional: Adjustable Vented Shelves DC 2 Way Fan Tray Unit with Cable access Vented doors 1Uor 2U Patch panel for service connection
Customer presentation DC Power will be proved on a 1U high din rail located at the top of the back of the rail, the DC cables will be presented using breakers or fuses appropriate to the supply ordered. The Protective Earth will be supplied via the AC connection. The Rack will be earthed to the Telecom Earth system. Other general services will be presented on 1 or 2 U panels located at the back of the rack below the DC Din power rail.
Floorspace Floorspace is raw technical floorspace sold on a per m2 basis with power packaged separately. Floorspace is available at POP and regen sites.
Standard Specification Caged and partitioned private suite Power packages from 500w/m2 to 2kw/m2 sized to include air conditioning. DC power provisioned to a maximum of 2KW/m2.
Events
This data center has timeline events listed. Typically events are related to M&A history, rebranding, capacity expansions etc.
May 2018 - M&A - Interoute Sofia
Company name: Interoute
Interoute was successfully acquired by GTT Communications in May 2018
Sep 2021 - M&A - GTT Sofia
Company name: GTT Communications
In September 2021, I Squared Capital acquired GTT Communications' infrastructure division and established it as an independent operating company named EXA Infrastructure
Pricing & Services
If you are looking for colocation, cloud, connectivity or other services in EXA Sofia, other data centers in Sofia or operated by EXA Infrastructure, please try our free quote service or reach out for a free consultation about your data center needs. We use a best effort process to qualify opportunities and route them to matching operators.
Advertisement
Nearest Data Centers
The below data centers are located closest to г 1784, Boulevard "Tsarigradsko shose" 115.