Aligned IAD-01

Aligned Data Centers
21890 Uunet Drive
20147 Ashburn
Virginia, USA
Visit Website

Suites
Remote Hands


26 acre data center campus, with a total of 370,000 square feet and 60 MW of power.

Facts
- Completed in 2019
- 26-acre campus
- Private, dedicated data center suites
- Concrete slab-on-grade and structured steel
- ASCE 7 occupancy category IV
- Data hall FM-120 and office FM-90 roof lift ratings
- Wind importance factor of 1.15
- Two bays with delivery platform and equipment trap
- Dedicated office space for rent
- Shared conference rooms and drop-in office pods
- 24x7x365 accessibility
- Industry-leading PUE

Security & Fire Protection
- 8’ Impasse steel security fencing with laser intrusion detection
- Five-layer security design
- Card reader access
- 24x7x365 on-site security guards
- Multiple checkpoints: mantraps, dual authentication (biometrics and RFID badge readers)
- Event-driven IP video surveillance and visual light-based alerts
- Separately zoned data halls
- Very Early Smoke Detection Apparatus (VESDA)
- Dual interlock pre-action system

Connectivity & Power
- Two diverse points of entry, per build
- Carrier-neutral
- On-net: Cogent, Crown Castle, Lumen, PacketFabric, SummitIG, Verizon (VCT & VCB), and Zayo
- Near-net: AquaComms, BT, Colt, Deutsche Telecom, GTT, Hurricane Electric, NTT, PCCW, Tata, Tennebris Fiber, TeliaSonera, major exchanges in NoVA, and many more
- Less than one mile from 21715 Filigree Court Carrier Hotel
- Major fiber thoroughfares within ~100 feet of facility
- Seamless build process for carriers not already built in
- Diverse meet-me-rooms and fiber entrances with dark fiber and lit services available
- Diverse and dedicated substations: expandable to 240MW
- Concurrently maintainable UPS
- N+2 power generation
- Redundant A+B distribution
- Revenue-grade metering

Cooling
- Our hot aisle containment strategy absorbs heat at its source,
- supporting standard and high power densities,
- allowing you to scale vertically and horizontally without stranding capacity
- Configurable to client needs (N, N+1, 2N)

Compliance
- System and Organization Control (SOC) 2 Type 2 and SOC 1 Type 2
- PCI DSS, HIPAA, HITECH, FISMA /NIST 800-53, and ISO 27001:2013

Aligned Ashburn IAD01 Spec Sheet.pdf
Aligned IAD-01 Pricing
If you are looking for colocation, cloud, connectivity or other services in Aligned IAD-01, or other data centers in Ashburn or by Aligned Data Centers, please try our free quote service or reach out for a free consultation about your data center needs.
Advertisement
Nearest Data Centers
DistanceData CenterAddress
0.18 milesIntergate.Ashburn21735 Red Rum Drive
0.18 milesWindstream Ashburn44200 Waxpool Rd
0.21 milesEquinix DC1321830 Uunet Way
0.25 milesDataBank IAD1 - Ashburn 21635 Red Rum Drive
0.28 milesAligned IAD-0221821 Uunet Drive
0.41 miles44274 Round Table Plaza, Bldg L (IAD39)44274 Round Table Plaza (Bldg L)
0.41 milesNTT Ashburn VA321583 Megawatt Drive
0.41 milesNTT Ashburn VA521583 Megawatt Drive
0.41 milesNTT Ashburn VA421583 Megawatt Drive
0.42 miles21625 Gresham Drive (ACC7)21625 Gresham Drive

Aligned Data Centers
Data Center Operator at
Aligned IAD-01
21890 Uunet Drive
Site Code: IAD-01
Headquartered in Plano, Texas

20