Kozma DC is located in the area Budapest, Hungary, and the colocation data center is not carrier neutral. The data center was last updated on 06-07-2010.
Building . Address: 1108 Budapest, Kozma u. 2. . Full size of machine room: 1,500 m² . False floor load bearing capacity: point-like; 50 kN/m² . Machine room's full height to ceiling, available for equipment installations: 3.7 metres . Fire rating: 60 minutes . Redundancy of power supply and building machinery (HVAC) systems: at least N + 1 . Availability of the power supply and air conditioning services: 99.999% Telecomm. connections . Two-side, independent optical links and microwave connection to Invitel's infrastructure . Additional optical fibres to connect customers via optical connections . Direct connections to the major Internet nodes (e.g. Invitel's DataCenter in Ilka Street, BIX, Infopark, Dataplex, etc.) . A radio connection can also be provided to the DataCenter . 3x10Gbps redundant connection to Invitel's other sites Power Supply and Cooling . Availability of the power and air conditioning services: 99.999% . 3 medium voltage power supply lines, each 1600 kVA/10kV (2 operating, 1 standby) . In 2 diesel groups, 2+2 1400-kVA "Cummins Power Generation" type generators in tandem mode . Under full load, the system can cover a power outage of 72 hours . 2N UPS systems, in a "3+1" configuration on either side, performance being 1650 kVA + 550 kVA, to ensure uninterrupted power supply between the loss of power and the run-up time of generators . Under full load, the system can cover a power outage of 30 minutes . In the machine rooms, A + B independent UPSs . 1600 kW cooling performance, with a 2N redundancy . Power saving cooling solutions (a combination of free cooling condensers and compact liquid chillers) . 40 indoor computer air conditioners, each with a capacity of 50 kW, c/w humidity maintenance, in an N+2 number per machine room . Air handling units to supply fresh, dust-free, heated/cooled air to the building Security . 24/7 security service . Closed-chain IP video monitoring and recording system in the whole outdoor facility area, as well as in interior spaces . Continuously monitored pass and intrusion detection system . Continuously monitored building supervision system . Machine rooms protected against conducted and radiated electromagnetic disturbances (EMC) . Early warning smoke detection system with aspiration-based and optical detectors . Delay between fire detection and start of extinguishing : 30 seconds . Extinguishing system: with FM-200 (HFC-227ea) extinguishing gas
Kozma DC Pricing/Quotes
If you are interested in receiving a quote for Invitel Telecommunication Inc., please try our free quote service.