Space
Size
. 255,000+ square feet
Deployments
. Cabinets, cages, private suites and
build-to-suit
. Rooftop space available
Power
. AC and DC
. Breakered and metered billing
Fit out
. Powered shell, infrastructured shell
and turn-key
Contract Structure
. Colocation license or NNN lease
Redundancy
. N, N+1 and 2N UPS and generator
Interconnection
. AWS Direct Connect availability
. Blended IP service
Exchanges
. CoreSite's Open Cloud Exchange and
Any2Exchange
Diversity
. Diverse POEs, MDFs and IDFs
Cross Connects
. Fiber, copper and coaxial (standard
2-day installation SLA with faster
emergency services available
Security
. Key card access
. Biometric scanners
. Mantrap entries
. Perimeter and interior IP-DVR cameras
. 24x7x365 security by CoreSite security
officers
. 8' perimeter fence with controlled site access
Structure
Floor Loading
. Floor 1: 250 LBS/SF
. Floor 2: 165 LBS/SF
Column Spacing
. Floor 1: 24' x 24'
. Floor 2: 48' x 48'
Clear Height
. 17' above 36" raised floor
Design Efficiency
Electrical
. Mitsubishi high-efficiency UPS systems
. Power taken at 26 KV to achieve rate
reduction and distribution efficiencies
. Design PUE = 1.35
Mechanical
. Chilled water with evaporative condensing
units and chillers for air- and water-side
economization with variable speed CRAHs
and ultrasonic humidification
. Design WUE = 0.35
Life Safety
. Dual-interlock pre-action dry-pipe sprinkler
system with VESDA
Lighting
. Lutron Eco-System lighting
Certifications
. LEED
. Provide the physical security necessary to
meet regulatory compliance requirements
such as HIPAA and FISMA
. Energy Star
. SSAE-16 Type 2
Corporate Amenities
. Office space and conference rooms
. 24x7x365 tech lounge with
televisions, couches and kitchen
Building Support
Loading Dock
. Exterior 48" dock-high with levelers
Package Service
. 24x7 package receipt and temp storage
Elevators
. Passenger: 7'w x 4'd x 9'h; 2,500 LBS
. Freight: 9'w x 11'd x 9'h; 10,000 LBS
On-site Parking
. 630 space garage
Storage and Staging
. Private and shared areas
Reliability
Electrical
. PSE&G
. Diverse utility feeds
. 24 hours of on-site fuel storage
Mechanical
. N+1 chillers, cooling towers, CRAHs
and chilled water pumps
. 24 hours of on-site water storage
Staffing
. 24x7x365 on-site, BICSI and CFOT
accredited personnel
. 24x7x365 remote hands
BMS Controls
. State-of-the-art mission critical controls
and monitoring
Uptime
. 100% uptime SLA
. Portfolio performance of six 9s (99.9999%)
If you are looking for colocation, cloud, connectivity or other services in NY2, or other data centers in Secaucus or by 247rack.com, please try our
about your data center needs.